Check the +5 volt pin (pin 5) on the programming port versus pin 7 (0 volts). If you suspect the settings have changed, compare the CPU’s port configuration to the port settings for your software.Ī bad programming port may also be the cause of this problem. Check that the default settings are 19200 baud, 8 data bits, 1 stop bit, and odd parity. You could also have the wrong communication settings.
#GE FANUC VERSAMAX SOFTWARE DOWNLOAD SERIES#
To check the cable’s operation, try to connect to another Series 90 PLC. This problem could also be the result of a faulty cable.
#GE FANUC VERSAMAX SOFTWARE DOWNLOAD SERIAL#
The causes of this problem may include a bad port on the PC, for which you can use the PC’s serial port to try to communicate with a separate device to check if it’s operating properly. My PLC Won’t Communicate with the Programming Port on my Series 90 CPU. If the OK LED light is out, the software can’t communicate. These will help you locate the source of your problem. If both of these look good, then use one of the programming packages (the three software programs mentioned above) to connect to the Series 90 programming port and check the PLC and I/O fault tables. Check the POWER LED (which will show the health of the power supply) and the OK LED (which will indicate the health of the CPU). You can determine the cause by referring to the LEDs on the power supply as well as the CPU. This should only be done when passwords aren’t a problem.
#GE FANUC VERSAMAX SOFTWARE DOWNLOAD DOWNLOAD#
You can do this by removing the CPU from the baseplate and shorting across two solder pads labeled “MEM CLR” for about ten seconds.Ī configuration with “Passwords Enabled” can be downloaded onto the CPU once the memory is erased.Īnother way to do this is to change the configuration being downloaded to a “Passwords Disabled” setting and then download the configuration onto the CPU. You may have to clear the memory by shorting out a super-capacitor on the CPU module in some cases. To do this, simply turn off the CPU, disconnect the battery, and turn the CPU back on with the battery still disconnected. When you disable passwords in a Series 90 CPU, the only way to download a configuration where the CPU is configured for “Passwords Enabled” is to completely erase the memory in the target CPU. This error happens when you try to download a configuration in which the CPU is configured for “Passwords Enabled” and the CPU being downloaded is set to “Passwords Disabled.” When I Try to Download the Configuration to my Series 90 CPU, the Download Fails because Passwords Are Disabled. This is the only software that’ll support new Series 90-30 and VersaMax CPUs and modules as they become available.
It supports all of the same PLCs that VersaPro Standard can as well as several of the newer 90-30s and VersaMax PLC that VersaPro Standard doesn’t. This is the current software package for Series 90-30 PLCs.
#GE FANUC VERSAMAX SOFTWARE DOWNLOAD WINDOWS#
Another Windows-based software package, which can run in Windows 2000, XP, and Vista.
We work to totally support your GE Fanuc Series 90-30 PLC, so whether you need repairs, advice, or just want to browse our frequently asked questions (FAQs) and online manuals, Qualitrol International is here to support you. When you need support for your 90-30 PLC, our engineers are just a call away.